HOUSEIR: COLOR-CODED RESIDENTIAL EDIT PROOF Prepared October 12, 2026. Conceptual architectural option, not construction documents. START HERE Open original-color-coded.ifc and changed-color-coded.ifc in an IFC viewer that honors surface styles. Magenta identifies the added partition/access. Hide roofs and spaces, or use a horizontal section, to see the ground floor. The opening is a void: it does not contain a door leaf, hardware or a door swing. Read original-object-guide.txt or changed-object-guide.txt with the matching IFC. Each guide lists every IfcProduct: original name, IFC class, stable GlobalId, category/color, container and measured world bounding dimensions. CSV versions provide the same index for filtering. Bounding sizes are not fabrication sizes. Public demo: https://houseir.unum11.com/demo.html Start with walkthrough.txt, then fill in review-scorecard.html or review-scorecard.txt. Review status: independent architect review pending. THE EDIT Source: KIT/IAI FZK residential architectural IFC4 model. Purpose: explore a screened work nook in part of the existing living area while retaining the original house and source information. Three joined, rectangular wall sections form a dogleg around the window and stair. All are on ground-floor Storey L1, 100 mm / 3.94 in thick and 2500 mm / 8 ft 2.43 in high. OfficeReturn: centerline (8000,300,0) to (8000,1550,0) mm. Length 1250 mm / 4 ft 1.21 in. Its front-wall junction stops short of the window recess. OfficeLink: centerline (7950,1600,0) to (9550,1600,0) mm. Length 1600 mm / 5 ft 2.99 in. Joins the two parallel sections at flush faces. OfficePartition, IFC GlobalId 2W7liKibrTU82Zsa6W56nw: - Centerline (9500,1650,0) to (9500,4010,0) mm. - Length 2360 mm / 7 ft 8.91 in. - Thickness 100 mm / 3.94 in; faces X=9450 and X=9550 mm. - Height 2500 mm / 8 ft 2.43 in. OfficePassage, IFC GlobalId 3fG5Ct6S5HHh1HieLIv8Ut: - Clear opening 1000 mm / 3 ft 3.37 in wide, 2100 mm / 6 ft 10.68 in high. - Starts 550 mm / 1 ft 9.65 in along OfficePartition, sill at floor level. - World Y=2200 to 3200 mm; cuts through the partition. The proposed work nook has an L-shaped inner planning footprint, with vertices (8050,300), (11700,300), (11700,4010), (9550,4010), (9550,1550), (8050,1550) mm. Its area is 9.8515 m2, approximately 106.04 square feet, excluding the access threshold strip. The narrower portion is 2150 mm / 7 ft 0.65 in wide. This is a planning measurement, not a newly certified room area. X/Y are source project axes; actual compass orientation is not asserted. No existing wall was removed and no floor was cut. Existing room boundaries and area records remain unchanged. The option needs room-boundary and area updates before it becomes a coordinated room redesign. WHY IT IS USEFUL A software team can convert an existing IFC to editable BIR, request a bounded architectural addition, and receive an IFC plus evidence that unrelated source products survived. Reviewers can find the addition by color and GlobalId. This demonstrates a specific additive workflow, not arbitrary renovation or permitting. ACTUAL VERIFICATION - 127 original IfcProducts retained; 131 in the changed model. - All original product semantic fingerprints retained. - All 107 existing tessellated meshes retain identical vertices and triangles. - Added products: three wall sections and one opening; no existing product removed. - Independent complete planar wall-surface check passed, including the cutout. Surface bounds are recorded per wall in verification.json, under the 1 mm contract. - Supporting floor: zero uncovered square meters beneath the new wall footprint. - Expected net volumes: 0.3125, 0.4000 and 0.3800 m3; total 1.0925 m3. Measured volumes and world bounds independently matched these requested values. - Conservative bounding-box screening found no overlap deeper than 1 mm between the new wall envelopes and existing physical elements/opening voids. This is not an exhaustive clearance or regulatory approval. - No new whole-model structural schema/attribute problems. The engine also ran its bounded touched-product EXPRESS checks, not full normative validation. - Negative control: a 4000 mm opening extending beyond its wall was rejected; no IFC was published for that request. - Recoloring changed only presentation entities. Saving and reopening each colored IFC retained all mesh vertices/triangles and introduced no new schema problems. - 35 architectural tests and 52 related generator, residual, IFC2X3, operation and service tests passed: 87 focused tests, not a fresh full-repository test run. DEFECT FOUND AND FIXED The first edit was rejected because a bare opening lost its requested name. The local compiler now preserves named bare-opening labels. Regression tests cover candidate publication and imported-source API edits. No gate was relaxed. The initial failed evidence remains in the workspace. Visual review also rejected an earlier straight-wall option: its endpoint met a window recess even though it did not intersect the glass. The final dogleg avoids that junction. The supplementary package checker now includes source opening voids as well as physical objects. The original engine's gate did not catch that design issue; no claim of comprehensive automatic architectural review is made. This package uses the fixed LOCAL API engine. The fix was NOT deployed to the hosted production API in this task. Conversion was reused by verified artifact hash; conversion and edit reports record their own compiler source digests because the label fix occurred between those steps. The edit itself was rerun and verified. COLOR LEGEND Warm gray: walls. Slate gray: floors/slabs. Terracotta: roof. Amber: structural framing. Green: doors. Sky blue: windows. Purple: stairs/railings. Pale translucent cyan: logical spaces. Magenta: added partition/access. Light gray: other/spatial/annotation objects. Colors are review overrides, not material specifications. Openings normally appear as voids. Spatial containers, annotations and non-body representations may have no visible surface to color; the text indexes still label them. IFC viewers may override colors. Viewer clipping and hidden roofs/spaces do not alter the IFCs. LIMITATIONS AND PROFESSIONAL REVIEW This source is architectural, without coordinated MEP. Zero service checks is NOT evidence of HVAC, electrical or plumbing coordination. No claim is made that this particular house was built or approved under a code. An architect should review furniture, circulation around the spiral stair, daylight, ventilation, egress, finishes, acoustics, partition support/connections and usefulness. MEP engineers must determine necessary outlets, lighting, controls, ventilation and heating/cooling changes. Update room boundaries and quantities if the option is adopted. Thickness is conceptual, not a tested fire or acoustic assembly. No door hardware, equipment sizing or permit detail is given. RAW AND COLORED FILES original-raw.ifc: exact source bytes. changed-raw.ifc: exact successful HouseIR edit output. *-color-coded.ifc: presentation-only derivatives for easier review. Source-fidelity claims apply to the raw pair. Separate verification shows that colored copies preserve their raw counterpart's geometry and non-style entities. PUBLIC EVIDENCE operations.json: exact requested operations. verification.json: scoped product, geometry and style checks. public-evidence.json: provenance, artifact hashes and rejected-request evidence. MANIFEST.json: hashes of this kit's files (except the manifest itself and its ZIP). Compiler scripts, local machine paths and full internal runtime reports are not included in this public bundle. Arrange a technical walkthrough to discuss replay. The raw and colored IFCs are byte-identical to the verified local package. Local viewer: from the extracted kit folder, run python -m http.server 8877 --bind 127.0.0.1, then open http://127.0.0.1:8877/review/ . Website navigation links outside the kit are intended for the public site; use the public URLs offline. LICENSE AND ATTRIBUTION Original: Institute for Automation and Applied Informatics (IAI), Karlsruhe Institute of Technology (KIT), Creative Commons Attribution 4.0 International. Model: https://huggingface.co/datasets/sylvainHellin/ifc-bench/resolve/main/projects/fzk_house/arc.ifc License source: https://huggingface.co/datasets/sylvainHellin/ifc-bench/resolve/main/projects/fzk_house/license.txt Original examples: https://www.ifcwiki.org/index.php?title=KIT_IFC_Examples License terms: https://creativecommons.org/licenses/by/4.0/ Adaptations by HouseIR: partition/access opening and review surface colors. No KIT/IAI endorsement is implied. Retain this attribution and source-license.txt with shared model copies. The source license text is included unchanged. The viewer bundles three.js; its MIT license is review/vendor/THREE-LICENSE.txt.