# Ironwood Ledge House: industrial modern, St. George, Utah

A two-storey, industrial modern house of about 13,000 sq ft, designed to the codes Utah has adopted
and to the published HOA rules of The Ledges (Sand Cove), St. George. It was built with the HouseIR
`compose_model` → `preflight_bir` → `propose_model` → `propose_edit` flow, and the accepted model
passed all 16 HouseIR checks.

This is a conceptual model, not construction documents. A Utah-licensed architect and engineers
still have to do the structure, the Manual J/S/D HVAC design, the plumbing sizing and the NEC load
calculation, and the city and the HOA still have to approve it (see "Still open" at the end).

## Files (all in `C:\Users\User 7\Downloads\Ironwood-Ledge-House\`)

| File | What it is |
|---|---|
| `Ironwood-Ledge-House.ifc` | The BIM model (IFC4), colour-coded by discipline. Opens in any IFC viewer, Revit, Archicad or BlenderBIM. |
| `Ironwood-Ledge-House-3D.html` | 3D viewer in the browser. Has a toggle for each system and "Services only" / "Building only" views. |
| `Ironwood-Ledge-House.bir` | The model as HouseIR text, one line per element (866 elements). |
| `drawings\drawings.pdf` | Draft sheet set: plans, sections and elevations by discipline. |
| `design-review.zip` | Design-review views and findings. |
| `project\` | The accepted HouseIR project: revision history, hashes, provenance. |

## Site and massing

- **Lot:** RE-20 zoning, about 0.6 to 1 acre, sloping down to the south. The street is on the north
  side, and the view and pool are on the south.
- **Main level (L1):** at street grade. Floor to roof is 5.0 m (16 ft 5 in), with 3.8 m (12 ft 6 in)
  ceilings. The top of the roof is about 5.35 m (17 ft 7 in) above the base elevation, which is under
  Sand Cove's 24 ft cap and the city's 40 ft cap. From the street it reads as one storey, as Sand Cove
  requires.
- **Walk-out lower level (LL):** 4.2 m floor to floor, with 2.85 m (9 ft 4 in) ceilings. It is built
  into the slope and opens to the south and east. The north and west walls are board-formed concrete
  retaining walls.
- **Plan:** a long east–west bar (44.4 m × 16.4 m), so the glass faces south (shaded) and north. There
  is no glass on the west face; the garage, mudroom and plant room sit on the west end as a heat buffer.
- **Street front, three masses:** the garage projects 1 m forward, the entry is recessed 1 m, and the
  kitchen and primary-suite mass sits between them. This answers Sand Cove's rule asking for at least
  three distinct masses.

## Floor areas

| | Net room area | Notes |
|---|---|---|
| Main level | 6,535 sq ft | excluding the 808 sq ft garage, the lift and the riser |
| Lower level | 5,639 sq ft | excluding the lift and the riser |
| **Total livable** | **12,174 sq ft net**, about **13,440 sq ft gross** | gross is measured to the outside face of the walls (ANSI Z765), garage excluded |

## Rooms

**Main level:** entry foyer (recessed, 1.5 m pivot door); steel gallery (the main spine, 926 sq ft);
great room (843); family room (630); dining (346); chef's kitchen (518) with scullery and pantry
(217); glass wine wall; powder room; library and office (376); guest suite 1 with bath and closet;
primary suite (bedroom 369, bath 241 with two basins, shower and tub, closet 217, vestibule 152);
mudroom and laundry; three-car garage (808); main-level air-handler room; AV closet; steel and glass
stair; elevator.

**Lower level (walk-out):** game room (720) and bar (204), both opening south; three guest suites,
each with its own bath and closet and a sliding door to the terrace; theater (513); gym (439);
sauna and steam (215); pool bath and changing (215); golf simulator (313); lower gallery; main plant
room (421); storage.

**5 bedrooms, 5 full baths and 1 powder room.**

## Materials (industrial modern, kept under the HOA's 38% reflectance limit)

| Element | Assembly |
|---|---|
| Main-level walls | Weathering-steel rainscreen on a ventilated cavity, R-7.5 mineral wool continuous insulation, steel stud with R-21 batts (286 mm) |
| Lower-level and retaining walls | Board-formed reinforced concrete 300 mm, waterproofing and drainage board, R-10 XPS inside (400 mm) |
| Floors | Polished concrete topping with radiant tubing on a composite steel deck |
| Roof | Flat roof on a steel deck, R-49 tapered polyiso, dark-grey membrane under 38% reflectance; drains run inside the walls (HOA rule) |
| Structure | Steel columns at every wall junction (94 columns) |
| Windows | Black steel-look frames with low-E glass, U ≤ 0.32 |

## Building systems in the model

**412 devices on 30 networks, with 0 clashes between systems** (minimum 10 mm clearance) and every
device connected:

- **Plumbing:** cold water, hot water, sanitary waste and vent stack, and storm drainage from the
  roof drains. Both floors are fed through one stacked riser shaft. The plant room holds the water
  entry, the water heater and a softener space (St. George water runs about 15 to 20 grains per gallon).
- **Fire sprinklers:** 62 heads (NFPA 13D or IRC P2904). See the code note below; for a house this
  size they are likely required.
- **HVAC:** supply, return and exhaust ducts on each floor, with an air handler on each level
  (main-level air-handler room and lower-level plant room). Plan on about 22 to 26 tons of variable-speed
  heat pumps in 5 to 7 zones, plus an ERV and kitchen make-up air.
- **Electrical:** power, lighting and data on each floor, plus feeders. There is a panel on each level
  and 86 circuits. A 400 to 600 A service is likely, and the NEC Article 220 load calculation decides it.
- **Alarms:** interconnected smoke alarms in every bedroom and on every level, and CO alarms on both
  levels.

## Code checklist (Utah State Construction Code, Title 15A, as of 2026)

| Requirement | Rule | This design |
|---|---|---|
| Codes in force | 2021 IRC, 2023 NEC, 2024 IFC (Utah amendments) | designed to these |
| Fire sprinklers | Utah 15A-5-203: a city may require them by ordinance above 10,000 sq ft of total floor area | included. Ask the St. George Fire Marshal whether the ordinance applies |
| Stair (Utah R311.7.5) | riser ≤ 8 in, tread ≥ 9 in, width ≥ 36 in, headroom ≥ 6 ft 8 in | 23 risers of about 7.2 in, 11 in treads, 47 in wide; the stairwell is open up to the main-level ceiling, so headroom is well over 80 in |
| Emergency escape (R310) | every sleeping room: sill ≤ 44 in, ≥ 5.7 sq ft net | lower-level guest suites and the primary bedroom have sliding doors to the outside. Guest suite 1 window: 1.6 × 1.5 m, 35 in sill (must be operable) |
| Ceiling height (R305) | ≥ 7 ft | 12 ft 6 in main level, 9 ft 4 in lower level |
| Garage separation (R302.5/R302.6) | no opening to a sleeping room; solid or 20-minute door; gypsum on the garage side | garage opens only into the mudroom |
| Smoke and CO alarms (R314, Utah R315.3) | smoke alarm in each bedroom and on each level; CO alarm on each level | both are in the model |
| Energy (Utah IRC Ch. 11, zone 3B) | walls R-21, ceiling R-38, windows U-0.32 | walls R-21 + R-7.5 ci; roof R-49; windows U ≤ 0.32 |
| Air sealing | blower door at 4.0 ACH50 or better | to be tested at completion |
| Loads | snow 21 psf ground; wind about 110 mph; seismic C or D; frost 12 in | for the structural engineer |
| Soils | St. George has expansive, collapsible and gypsum soils | a geotechnical report is needed before foundation design |

## HOA checklist (The Ledges, Sand Cove neighborhood guidelines)

| Rule | This design |
|---|---|
| Height ≤ 24 ft from base elevation; 1 storey above pad frontage grade | about 17.6 ft; the second storey is a walk-out below the street level |
| Flat roofs allowed; drains built into walls; roof protrusions screened | flat parapet-style roofs; mechanical equipment indoors |
| Earth-tone, non-glossy finishes, ≤ 38% reflectance | weathering steel, board-formed concrete, dark-grey roof |
| Metal-clad windows with low-E glass | black metal frames, low-E |
| At most 3 garage bays; sectional doors at most 9 ft high | 3 bays, 7 ft 10 in doors |
| HVAC hidden from the street | air handlers indoors; condensers go in a screened yard on the east side |
| Lighting indirect and shielded | to be shown on the lighting plan |
| Low-water landscaping | turf ≤ 8% of the lot (Washington County rule); desert plants from the HOA's plant list |

## Still open (honest gaps)

1. **St. George's own ordinances could not be read** (the city's code website blocks automated
   access). Confirm these with St. George Community Development, (435) 627-4003, and the Fire Marshal:
   - whether the sprinkler ordinance applies
   - the current wind, seismic and frost table
   - current setbacks
2. **Get the current guidelines from the HOA** and a lot-specific building envelope. Only The Ledges
   publishes its guidelines online; Stone Cliff, Entrada and Desert Color do not.
3. **Not engineered.** HouseIR keeps pipes, ducts and cables apart and connected, but it does not size
   them, slope the drains, calculate loads, or check fixture clearances against code. Receptacle counts
   are conceptual: the model has 2 receptacles per bedroom, and the NEC 12 ft rule needs more.
4. **The drawings are a draft.** The architectural sheets are produced, but the drawing compiler cannot
   yet draw the plumbing, duct and cable networks on the MEP sheets. For now, view those in the IFC
   or the 3D viewer.
5. **The sanitary drain runs about 4.6 m under the on-grade west slab.** That is normal for a sewer
   line, but HouseIR flags it as a pipe exposed under an overhang.
6. **The design review flags a "long blank front wall".** That wall is the buried lower-level
   retaining wall, which cannot be seen, so the flag is a false positive in HouseIR.
7. **Not yet modelled:** the pool, cabana, site walls and solar. Solar must sit low behind a parapet
   under the HOA rules.