EXAMPLE BUILD · ST. GEORGE, UTAH

Ironwood Ledge House.
13,000 sq ft, every system modelled.

A two-storey industrial-modern house on a downslope lot. An AI agent designed it with HouseIR, from the research through to an accepted model with plumbing, HVAC, electrical and fire sprinklers.

Conceptual design · not construction documents

Street-side view: a long flat-roofed bar with three garage doors projecting forward and a recessed entry.
Street side (north): it reads as one storey, with three distinct masses.
View side elevation: the main level above and the walk-out lower level below, both with large sliding doors.
View side (south): the walk-out lower level opens onto the terrace.

THE FULL MODEL · 816 ELEMENTS

Move around the whole house.

Drag to orbit, right-drag to pan, scroll to zoom, click any part to inspect it. Solo a discipline (architecture, structure, plumbing, fire, HVAC or electrical), make the walls and structure see-through, or look at one level at a time.

Open the model on its own page ↗

12,174

sq ft net livable (about 13,440 gross)

16 / 16

HouseIR model checks passed

412

devices on 30 connected networks

0

clashes between building systems

THE HOUSE

Two storeys that read as one.

The main level sits at street grade. A walk-out lower level is built into the slope and opens south and east to the view. The roof is about 17.6 ft above the street, under The Ledges' 24 ft cap.

  • 5 bedroom suites, 5 full baths and a powder room
  • Great room, chef's kitchen with scullery, dining, family room, library
  • Theater, gym, sauna and steam, golf simulator, game room and bar
  • Elevator, steel and glass stair, three-car garage
  • A long east–west bar with no glass facing the hot west sun

INDUSTRIAL MODERN

Steel, concrete, glass.

  • Weathering-steel rainscreen over R-21 + R-7.5 continuous insulation
  • Board-formed concrete retaining walls on the lower level
  • Steel frame (94 columns) and composite steel decks
  • Polished concrete floors with radiant tubing
  • Flat roofs, R-49, dark-grey membrane under 38% reflectance
  • Black metal windows, low-E glass, U ≤ 0.32

BUILDING SYSTEMS

Plumbing, HVAC, electrical and sprinklers.

Plumbing

Cold and hot water, sanitary waste and vent, and roof storm drainage, fed through one stacked riser. The plant room has space for the water heater and a softener for St. George's hard water.

HVAC and fire

Supply, return and exhaust ducts with an air handler on each level. 62 sprinkler heads, because St. George may require them above 10,000 sq ft.

Electrical

Power, lighting and data on both floors, a panel on each level and 86 circuits. Interconnected smoke alarms, plus CO alarms on both levels as Utah requires.

CODE AND HOA

Designed to Utah's adopted codes.

RuleRequirementThis design
Codes in force2021 IRC, 2023 NEC, 2024 IFC with Utah amendmentsDesigned to these
Fire sprinklersUtah 15A-5-203: a city may require them above 10,000 sq ftIncluded; confirm with the St. George Fire Marshal
Stairs (Utah R311.7.5)Riser ≤ 8 in, tread ≥ 9 in, width ≥ 36 inAbout 7.2 in risers, 11 in treads, 47 in wide
Escape openings (R310)Every bedroomSliding doors to outside, or a qualifying window
Smoke and CO alarmsEach bedroom and level; CO on each level (Utah R315.3)Both in the model
Energy (zone 3B)Walls R-21, ceiling R-38, windows U-0.32Walls R-21 + R-7.5 ci, roof R-49, windows U ≤ 0.32
HOA height24 ft from base elevation; one storey above the streetAbout 17.6 ft; second storey is a walk-out below
HOA finishesEarth tones, ≤ 38% reflectance, metal-clad low-E windowsWeathering steel, concrete, dark-grey roof, black metal windows
HOA garage and massingAt most 3 bays, doors ≤ 9 ft; at least 3 masses3 bays at 7 ft 10 in; garage forward, entry recessed

HOA rules are from the published Sand Cove guidelines at The Ledges, the only St. George luxury community that publishes them online. A real lot needs its own HOA guidelines and building envelope.

HONEST GAPS

What this model does not settle.

  1. Not engineered. Pipes, ducts and cables are routed and connected, but not sized. There is no structural design or load calculation yet.
  2. City ordinances to confirm. St. George's code site blocks automated reading. The sprinkler ordinance, wind and seismic values and setbacks need confirming with the city.
  3. Receptacle counts are conceptual. Bedrooms show two each; code requires more.
  4. Drawings are a draft. The MEP sheets do not yet draw the pipe, duct and cable networks. Use the 3D model or IFC for those.
  5. Not modelled: pool, cabana, site walls and solar.

DOWNLOADS

Take the model with you.

A Utah-licensed architect and engineers still need to complete the design, and the city and HOA need to approve it, before anything is built.